Heavy Duty Binary / Gray Output Converter NCV-40H

Description

Heavy Duty NCV-40H

NCV-40H is digital binary or gray code output converter which is connecting with heavy duty ABSOCODER position sensors

Download   Contact

Model coding

NCV-40H[1]N[2]

[1]Output code
Code Output code
B Binary
G Gray
[2]Applicable sensor
Code Applicable sensor
M5 MRE-1024S16TS100

ABSOCODER Basic Configuration

  • Position Sensor
    •  
    • Heavy Duty Multi-turn type ABSOCODER Sensor
  • Cable
    • Cable for heavy duty 5S-RBT-4355,5S-RBT-4344,5S-SLA-5756
  • Converter / Controller
    • NCV-40H

Specification

General specification

Item Specification
Power supply voltage 24VDC±10% (including ripple)
Power consumption 10W or less
Insulation resistance 20MΩ or more between external DC power terminals and ground
(by 500 VDC insulation resistance tester)
Withstand voltage 500 VAC, 60Hz for 1 minute between external DC power terminals and ground
Vibration resistance 20m/s2 10〜500Hz, 10cycles of 5 minutes in 3 directions, conforms to JIS C 0040 standard
Ambient operating temperature 0 ~ +55℃ (No freezing)
(Surrounding air temperature rating of 55℃ maximum)
Ambient operating humidity 20 ~ 90 %RH (No condensation)
Grounding Must be securely grounded (ground resistance of 100 ohm or less)
Construction Book-shelf type within enclosure, DIN rail mountable
Outside dimension (mm) 39(W)×155(H)×93(D) Refer to dimensions for details.
Mass Approx. 0.4kg

Performance Specification

Item Specification
Converter model NCV-40HBNM5, NCV-40HGNM5
Number of detection axes 1
Position data
sampling time
0.1ms
Status output signal Latch pulse (Position data reading timing) : 1 point
System ready : 1 point
Error : 1 point
Input signals Position data hold signal : 1 point
Zero point setting signal : 1 point
Error clear signal : 1 point
Front panel function Zero point setting, error clear
Switch
(on rear face of product)
Position data increase/decrease direction setting (CW / CCW) : 1point
Position data update cycle Edge timing 0.1ms
0.2ms
0.4ms
0.8ms
Level timing 1 0.8ms
1.6ms
3.2ms
6.4ms
Level timing 2 3.2ms
6.4ms
12.8ms
25.6ms
51.2ms
HOLD signal format Transparent format
PC synchro format
LP signal logic (Non-inverted/Inverted): 1 point
Zero point setting function selection (Enabled/Disabled): 1 point
Clearing method setting of the sensor disconnected error
(auto clearing / manual clearing): 1-point
Monitor LED Output state monitor Position data output, System ready output, Error output
Input state monitor HOLD input, zero point setting input, error clear input
Error state monitor Sensor disconnected error, Memory error,
Low power error, Sensor power supply error,
Switch setting error

Number of divisions, resolution, and sensor cable length of the ABSOCODER sensor

MRE Multi-turn type (High-resolution)

Item Specification
Converter model NCV-40HBNM5, NCV-40HGNM5
Applicable sensor MRE-1024S16TS100
Total number of turns 1024
Divisions/Turn 65536(216)
Total number of divisions 67108864(226)
Position detection format Absolute position detection
Max. sensor
cable length
5S-SLA 300m
5S-RBT 100m

I/O spcification

Item Specification
Converter model NCV-40HBNM5, NCV-40HGNM5
Input Input signals HD (Position data HOLD) : 1 point
ZPS (Zero point setting signal) : 1 point
CLR (Error clear signal) : 1 point
Input circuit DC input, photo-coupler isolation
Input logic Negative logic
Rated input voltage 12 ~ 24VDC (10 ~ 30VDC)
Rated input current 10mA (24VDC)
ON voltage 10VDC or more
OFF voltage 2VDC or less
Output Output signals Position data D0D25: 26points
  LP (Latch pulse: position data reading timing): 1 point
NOR (System Ready) : 1 point
ERR (Error): 1 point
Output circuit Transistor (open drain sink) output, photo-coupler isolation
Output logic Negative logic
Rated load voltage 12 ~ 24VDC (30VDC max.)
Max. load current 50mA / point
Max. voltage drop when ON 0.8 V or less

Dimensions

  • PDF Download

Application Introduction