PLC Module Converter

Description

PLC Module Converter

NSD smart PLC built-in converters provide an extremely reliable performance and present a variety of options to the customers.

Download   Contact

VS-R262B

VS-R262B is Binary Code output NSD smart PLC built-in controller for MELSEC iQ-R series PLC.

Download the profile (CSP+) for MELSEC iQ-R from the download page (Open Network Definition File).

VS-R262B

Model coding

VS-R262B-[1]

[1]Applicable sensor
Code Applicable sensor
VP VRE-P028/VRE-P062
MP MRE-32SP062/MRE-G□SP062(□ : 64/128/160/256/320)

Applicable System

Programmable
controller CPU
R00CPU R01CPU R02CPU R04CPU R08CPU R16CPU
R32CPU R120CPU        
Programmable
controller CPU
(CC-Link IE embedded)
R04ENCPU R08ENCPU R16ENCPU R32ENCPU R120ENCPU  
Process CPU *1 R08PCPU R16PCPU R32PCPU R120PCPU    
Safety CPU *2 R08SFCPU R16SFCPU R32SFCPU R120SFCPU    
C Controller *3 R12CCPU-V          
CC-Link IE Field
Network
remote head module
RJ72GF15-T2          

*1: When using the redundant mode, the redundant extension base unit (R68WRB) should be used.
For details of the redundant extension base unit, refer to the following manual.
 - MELSEC iQ-R Module Configuration Manual (SH081262)
The inter-module synchronization function is not available when our unit is mounted on the redundant extension base unit.

*2: Some functions are not supported by CPU. For details of the unsupported functions, refer to the following manual.
 - MELSEC iQ-R CPU Module User's Manual (Startup) (SH081263)
 - MELSEC iQ-R CPU Module User's Manual (Application) (SH081264)

*3: Our CSP+ files cannot be used with the CW Configurator (engineering software) manufactured by Mitsubishi Electric Corporation.
When specifying our module in the CW Configurator, select [Add New Module] from "Module Information" in the Navigation Window, and then select "Base Mounted Type General Module" ⇒ "Gen. Intelligent Module (1 slot)".

ABSOCODER Basic Configuration

  • Position Sensor
    •  
    • Single Turn Rotary Position Sensor
    •  
    •  
    • Multi Turn Rotary Position Sensor
  • Cable
    • Cable 3P-S-0102/3P-RBT-0102
    • Cable 4P-S-0102/4P-RBT-0102
  • Converter / Controller
    • VS-R262B

Specification

General specification

Item Specifications
Operating ambient
temperature
0 to 55℃ (When an extended temperature range base unit is not used)
0 to 60℃ (When an extended temperature range base unit is used)
Storage ambient
temperature
-25 to 75℃
Operating ambient
humidity
5 to 95%RH, non-condensing
Storage ambient
humidity
5 to 95%RH, non-condensing
Vibration resistance Compliant with
JIS B 3502 and
IEC 61131-2
Frequency Constant
acceleration
Half amplitude Sweep count
Under
intermittent
vibration
5 to 8.4Hz 3.5mm 10 times each in
X, Y, Z directions
8.4 to 150Hz 9.8m/s2
Under continuous
vibration
5 to 8.4Hz 1.75mm
8.4 to 150Hz 4.9m/s2
Shock resistance Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times each in X, Y, and Z bidirections)
Operating atmosphere No corrosive gases, flammable gases, less conductive dust
Operating altitude 0 to 2000m
Installation location Inside a control panel
Overvoltage category II or less
Pollution degree 2 or less
Internal power
consumption
0.7 A (5 VDC)
Mass 0.2kg

Performance Specification

Item Specification
Converter model VS-R262B-VP VS-R262B-MP
Applicable sensor VRE-P028
VRE-P062
MRE-32SP062 MRE-G□SP062
Position detection format Absolute position detection
Number of divisions 8192 Divisions×1 Turn 4096 Divisions×32 Turns

409.6 Divisions×320 Turns
Number of detection axes 2
Data setting method PLC CPU program
Position data
sampling time
0.1ms
Number of I/O points occupied 32 points (I/O assignment: intelligent)
Setting value memory Non-volatile memories
Auxiliary functions Current position detection, current position value setting
Max.
sensor
cable length
Standard(S) 100m 100m 100m
Robotic(RBT) 100m 40m 70m

Dimensions

  • PDF Download

VS-QA62

VS-QA62 is NSD smart PLC built-in controller for MELSEC-Q series PLC of Mitsubishi which is directly installed in PLC module without any wiring. VS-QA62 provides system motion control with limit switches output and all the parameters can be set by NSD programming software with your PC.

VS-QA62

Model coding

VS-QA62-[1]

[1]Applicable sensor
Code Applicable sensor
M2PG MRE-32SP062/MRE-G□SP062(□ : 64/128/160/256/320)
L VLS-256PWB/VLS-512PWB/VLS-1024PW

Contact us about other specifications.

Applicable System

 
Programmable
controller
CPU
Q00JCPU Q00CPU Q01CPU Q02CPU Q02HCPU Q06HCPU
Q12HCPU Q25HCPU Q02PHCPU Q06PHCPU Q12PHCPU Q25PHCPU
Q04UDPVCPU Q06UDPVCPU Q13UDPVCPU Q26UDPVCPU Q12PRHCPU Q25PRHCPU
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU Q03UDCPU Q04UDHCPU
Q06UDHCPU Q10UDHCPU Q13UDHCPU Q20UDHCPU Q26UDHCPU Q03UDECPU
Q04UDEHCPU Q06UDEHCPU Q10UDEHCPU Q13UDEHCPU Q20UDEHCPU Q26UDEHCPU
Q50UDEHCPU Q100UDEHCPU Q03UDVCPU Q04UDVCPU Q06UDVCPU Q13UDVCPU
Q26UDVCPU Q06CCPU-V Q06CCPU-V-B Q12DCCPU-V Q24DHCCPU-V Q24DHCCPU-LS
Q01WCPU-W1-J Q01WCPU-W1-CF-J Q01WCPU-W1-E
Q01WCPU-W1-CF-E PPC-100-DC5511 PPC-100-DC5311
Remoto
I/O module
QJ72LP25-25 QJ72LP25G QJ72BR15  

ABSOCODER Basic Configuration

  • Position Sensor
    •  
    • Multi Turn Rotary Position Sensor
    •  
    •  
    • Linear Position Sensor
  • Cable
    • Cable 4P-S-0102/4P-RBT-0102
    • Cable 4P-RBT-0103/4P-S-0102/4P-RBT-0102
  • Converter / Controller
    • VS-QA62

Specification

General specification

Item Specifications
Operating ambient
temperature
0 to 55℃
Storage ambient
temperature
-25 to 75℃
Operating ambient
humidity
5 to 95%RH, non-condensing
Storage ambient
humidity
Vibration resistance Compliant with
JIS B 3502 and
IEC 61131-2
Frequency Constant
acceleration
Half amplitude Sweep count
Under
intermittent
vibration
5 to 8.4Hz 3.5mm 10 times each in
X, Y, Z directions
8.4 to 150Hz 9.8m/s2
Under continuous
vibration
5 to 8.4Hz 1.75mm
8.4 to 150Hz 4.9m/s2
Shock resistance Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times each in 3 directions X, Y, Z)
Operating atmosphere No corrosive gases
Operating altitude 0 to 2000m
Installation location Inside a control panel
Overvoltage category II or less
Pollution degree 2 or less
Equipment class Class I
Internal power
consumption
0.7 A (5 VDC)
Mass 0.2kg

Performance Specification

Item Specification
Converter model VS-QA62-M2PG VS-QA62-L
Applicable sensor MRE-32SP062 MRE-G□SP062 VLS-□PW
Position detection format Absolute position detection
Number of divisions 4096 Divisions×32 Turns ~ 409.6 Divisions×320 Turns 256 ~ 1024mm/65536 Divisions
Number of detection axes 1
Data setting method PLC CPU program
Positioning
function
(speed switching
control)
Control format Unidirectional positioning or Bidirectional positioning
Control output Forward (FWD), Reverse (RVS), High-speed, Low-speed, Brake release, In-position, Positioning in progress, Operation error
Positioning
function
(acceleration/decel
eration control)
Control format Unidirectional positioning or Bidirectional positioning
Control output Forward (FWD), Reverse (RVS), Brake release, In-position, Positioning in progress, Operation error, Speed command
Switch output
function
Number of programs
(Panel display)
1
Number of
switch outputs
For switch output function only
I/O output: 8 points, Device X: 8 points, Buffer memory: 16 points
For switch output and positioning function
I/O output: 3 points, Device X: 0 points, Buffer memory: 16 points
Number of multi-dogs 5 times for each switch output
Sampling time
(Response time)
Switch output
Positioning output
0.4ms (0.8ms)
Current position output 0.2ms (0.4ms)
Number of I/O points occupied 32 points (I/O assignment: intelligent)
Setting value memory Non-volatile memories
Auxiliary functions Current position detection, positioning function, switch outputs, current position preset, JOG operation
Max. sensor
cable length
Standard(S) 100m 100m 100m
Robotic(RBT) 40m 70m 50m

I/O spcification

Item Specification
Input Input signals Current position preset input 2 points
Input circuit DC input, photo-coupler isolation
Rated input voltage 12VDC 24VDC
Rated input current 3mA 6.5mA
Voltage range to be used 10.2 to 30VDC
ON voltage 10VDC or more
OFF voltage 2VDC or less
Common connections 1 common for 2 points (common terminal: 11, 12)
Output Output
signals
For current position
detection only
No outpt
For switch
output function only
Switch output 8 points
For switch output &
positioning functions
Switch output 0 point
Positioning output 8 points
Output circuit Photo-coupler isolation
Rated load voltage 12/24VDC
Load voltage range used 10.2 to 30VDC
Max. load current 50mA
Max. voltage drop when ON 2.0V or less at 50mA, 1.7V or less at 10mA
Common connections 1 common for 8 points (common terminal: 24, 25)
Pulse
Output
Output signals A+/A-, B+/B-
Output circuit Line driver output (equivalent to AM26C31C)
Max. load current ±20mA max./1point
Differential output voltage 2.0V or more (Io=20mA)
Isolation format Photo-coupler isolation
Min. load resistance 100Ω min.
External power supply *1 0.2 A(5VDC : 4.75 to 5.25VDC)
Max. frequency 100 kHz
Analog
Output
Output signals Analog+ / Analog-
Isolation method Photo-coupler isolation
Output voltage range -10V to +10VDC
Output voltage resolution 0.3051 mV (-10V to +10V / 65536 divisions)
Updating cycle 0.4ms
External cable connection format 26-points connector
  • *1 : Pulse output circuits require the external supply voltage (5 VDC).

Dimensions

  • PDF Download

VS-QA262B

VS-QA262B is Binary Code output NSD smart PLC built-in controller for MELSEC-Q series PLC with 2 sensor channels.

VS-QA262B

Model coding

VS-QA262B-[1]

[1]Applicable sensor
Code Applicable sensor
V1PG VRE-P028/VRE-P062
V2 VRE-16TS062
M2PG MRE-32SP062/MRE-G□SP062(□ : 64/128/160/256/320)
LC CSA Cylinder

Contact us about other specifications.

Applicable System

Programmable
controller
CPU
Q00JCPU Q00CPU Q01CPU Q02CPU Q02HCPU Q06HCPU
Q12HCPU Q25HCPU Q02PHCPU Q06PHCPU Q12PHCPU Q25PHCPU
Q04UDPVCPU Q06UDPVCPU Q13UDPVCPU Q26UDPVCPU Q12PRHCPU Q25PRHCPU
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU Q03UDCPU Q04UDHCPU
Q06UDHCPU Q10UDHCPU Q13UDHCPU Q20UDHCPU Q26UDHCPU Q03UDECPU
Q04UDEHCPU Q06UDEHCPU Q10UDEHCPU Q13UDEHCPU Q20UDEHCPU Q26UDEHCPU
Q50UDEHCPU Q100UDEHCPU Q03UDVCPU Q04UDVCPU Q06UDVCPU Q13UDVCPU
Q26UDVCPU Q06CCPU-V Q06CCPU-V-B Q12DCCPU-V Q24DHCCPU-V Q24DHCCPU-LS
Q01WCPU-W1-J Q01WCPU-W1-CF-J Q01WCPU-W1-E
Q01WCPU-W1-CF-E PPC-100-DC5511 PPC-100-DC5311
Remoto
I/O module
QJ72LP25-25 QJ72LP25G QJ72BR15  

ABSOCODER Basic Configuration

  • Position Sensor
    •  
    • Single Turn Rotary Position Sensor
    •  
    •  
    • Single Turn Rotary Position Sensor
    •  
    •  
    • Multi Turn Rotary Position Sensor
    •  
    •  
    • Position Sensing Smart Cylinder
  • Cable
    • Cable 3P-S-0102/3P-RBT-0102
    • Cable 3S-RBT-0103/3S-RBT-0102
    • Cable 4P-S-0102/4P-RBT-0102
    • Cable 3P-S-0102/3P-RBT-0102
  • Converter / Controller
    • VS-QA262B

Specification

General specification

Item Specifications
Operating ambient
temperature
0 to 55℃
Storage ambient
temperature
-25 to 75℃
Operating ambient
humidity
5 to 95%RH, non-condensing
Storage ambient
humidity
Vibration resistance Compliant with
JIS B 3502 and
IEC 61131-2
Frequency Constant
acceleration
Half amplitude Sweep count
Under
intermittent
vibration
5 to 8.4Hz 3.5mm 10 times each in
X, Y, Z directions
8.4 to 150Hz 9.8m/s2
Under continuous
vibration
5 to 8.4Hz 1.75mm
8.4 to 150Hz 4.9m/s2
Shock resistance Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times each in 3 directions X, Y, Z)
Operating atmosphere No corrosive gases
Operating altitude 0 to 2000m
Installation location Inside a control panel
Overvoltage category II or less
Pollution degree 2 or less
Equipment class Class I
Internal power
consumption
0.7 A (5 VDC)
Mass 0.2kg

Performance Specification

Item Specification
Converter model VS-QA262B-M2PG VS-QA262B-V1PG VS-QA262B-V2
Applicable sensor MRE-32SP062 MRE-G□SP062 VRE-P028
VRE-P062
VRE-16TS062
Position detection format Absolute position detection
Number of divisions 4096 Divisions×32 Turns ~ 409.6 Divisions×320 Turns 8192 Divisions×1 Turn 65536 Divisions×1 Turn
Number of detection axes 2
Data setting method PLC CPU program
Position data sampling time 0.4ms
Response time 0.8ms
Number of
I/O points occupied
32 points (I/O assignment: intelligent)
Setting value memory Non-volatile memories
Auxiliary functions Current position detection, current position value setting
Max. sensor
cable length
Standard(S) 100m 100m 100m -
Robotic(RBT) 40m 70m 100m 100m
Item Specification
Converter model VS-QA262B-LC
Applicable sensor CYLNUC
CSA
Position detection format Semi - Absolute position detection
Number of divisions 12.8mm/8192 Divisions×pitch count
Number of detection axes 2
Data setting method PLC CPU program
Position data sampling time 0.4ms
Response time 0.8ms
Number of
I/O points occupied
32 points (I/O assignment: intelligent)
Setting value memory Non-volatile memories
Auxiliary functions Current position detection, current position value setting
Max. sensor
cable length
Standard(S) 100m
Robotic(RBT) 50m

Dimensions

  • PDF Download

VS-QA262

VS-QA262 is NSD smart PLC built-in controller for MELSEC-Q series with 2 sensor channels.

VS-QA262

Model coding

VS-QA262-[1]

[1]Applicable sensor
Code Applicable sensor
M2PG MRE-32SP062/MRE-G□SP062(□ : 64/128/160/256/320)
L VLS-256PWB/VLS-512PWB/VLS-1024PW

Contact us about other specifications.

Applicable System

Programmable
controller
CPU
Q00JCPU Q00CPU Q01CPU Q02CPU Q02HCPU Q06HCPU
Q12HCPU Q25HCPU Q02PHCPU Q06PHCPU Q12PHCPU Q25PHCPU
Q04UDPVCPU Q06UDPVCPU Q13UDPVCPU Q26UDPVCPU Q12PRHCPU Q25PRHCPU
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU Q03UDCPU Q04UDHCPU
Q06UDHCPU Q10UDHCPU Q13UDHCPU Q20UDHCPU Q26UDHCPU Q03UDECPU
Q04UDEHCPU Q06UDEHCPU Q10UDEHCPU Q13UDEHCPU Q20UDEHCPU Q26UDEHCPU
Q50UDEHCPU Q100UDEHCPU Q03UDVCPU Q04UDVCPU Q06UDVCPU Q13UDVCPU
Q26UDVCPU Q06CCPU-V Q06CCPU-V-B Q12DCCPU-V Q24DHCCPU-V Q24DHCCPU-LS
Q01WCPU-W1-J Q01WCPU-W1-CF-J Q01WCPU-W1-E
Q01WCPU-W1-CF-E PPC-100-DC5511 PPC-100-DC5311
Remoto
I/O module
QJ72LP25-25 QJ72LP25G QJ72BR15  

ABSOCODER Basic Configuration

  • Position Sensor
    •  
    • Multi Turn Rotary Position Sensor
    •  
    •  
    • Linear Position Sensor
  • Cable
    • Cable 4P-S-0102/4P-RBT-0102
    • Cable 4P-RBT-0103/4P-S-0102/4P-RBT-0102
  • Converter / Controller
    • VS-QA262

Specification

General specification

Item Specifications
Operating ambient
temperature
0 to 55℃
Storage ambient
temperature
-25 to 75℃
Operating ambient
humidity
5 to 95%RH, non-condensing
Storage ambient
humidity
Vibration resistance Compliant with
JIS B 3502 and
IEC 61131-2
Frequency Constant
acceleration
Half amplitude Sweep count
Under
intermittent
vibration
5 to 8.4Hz 3.5mm 10 times each in
X, Y, Z directions
8.4 to 150Hz 9.8m/s2
Under continuous
vibration
5 to 8.4Hz 1.75mm
8.4 to 150Hz 4.9m/s2
Shock resistance Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times each in 3 directions X, Y, Z)
Operating atmosphere No corrosive gases
Operating altitude 0 to 2000m
Installation location Inside a control panel
Overvoltage category II or less
Pollution degree 2 or less
Equipment class Class I
Internal power
consumption
0.7 A (5 VDC)
Mass 0.2kg

Performance Specification

Item Specification
Converter model VS-QA262-M2PG VS-QA262-L
Applicable sensor MRE-32SP062 MRE-G□SP062 VLS-□PW
Position detection format Absolute position detection
Number of divisions 4096 Divisions×32 Turns
to
409.6 Divisions×320 Turns
256 ~ 1024mm/65536 Divisions
Number of detection axes 2
Data setting method PLC CPU program
Positioning function Control format Unidirectional positioning or Bidirectional positioning
Control output Forward (FWD), Reverse (RVS), High-speed, Low-speed, Brake release, In-position, Positioning in progress, Operation error
Switch output
function
Number of programs 9
Number of switch outputs For switch output function only
Device X: 8 points
Buffer memory: 16 points
Number of multi-dogs 10 times for each switch output
Position data
sampling time
Switch output
Positioning output
1.6ms
Current position output 0.8ms
Response time Switch output
Positioning output
3.2ms
Current position output 1.6ms
Number of I/O points occupied 32 points (I/O assignment: intelligent)
Setting value memory Non-volatile memories
Auxiliary functions Current position detection, positioning function, switch outputs, current position preset, JOG operation
Max. sensor
cable length
Standard(S) 100m 100m 100m
Robotic(RBT) 40m 70m 50m

Dimensions

  • PDF Download

Application Introduction